Sun Microsystems SG-XPCIE1FC-EM8-Z Network Card User Manual


 
16 Sun StorageTek 8 Gb FC PCI-Express HBA, Emulex Installation Guide December 2008
Testing the Installation
This section contains the following topics:
“To Verify Proper Installation (for the Solaris OS)” on page 17
“To Verify Attached Storage (for the Solaris OS)” on page 21
To Verify Proper Installation (for the Solaris OS)
1. Use the show-devs command at the ok prompt to list the installed devices.
The HBA can be identified in the output by looking for the SUNW,emlxs@n and
SUNW,emlxs@n,1 node names, where n is usually a single-digit number from 0
to 9. In this example, there are two dual port (SG-XPCIE2FC-EM8-Z) and one
single port (SG-XPCIE1FC-EM8-Z) HBAs installed.
Slow Blink Off Normal – Link Down or not started
Slow Blink On Not Defined
Slow Blink Slow Blink Off-line for Download
Slow Blink Fast Blink Restricted Off-line Mode (Waiting for Restart)
Slow Blink Flashing Restricted Off-line Mode, Test Active
Fast blink Off Debug Monitor in Restricted Mode
Fast blink On Not Defined
{0} ok show-devs
/pci@7c0/pci@0
/pci@7c0/pci@0/pci@9
/pci@7c0/pci@0/pci@8
/pci@7c0/pci@0/pci@2
/pci@7c0/pci@0/pci@2
/pci@7c0/pci@0/pci@1
/pci@7c0/pci@0/pci@9/SUNW,emlxs@0,1
/pci@7c0/pci@0/pci@9/SUNW,emlxs@0
/pci@7c0/pci@0/pci@9/SUNW,emlxs@0,1/fp@0,0
TABLE 2-2 LED Status (Continued)
Green LED Yellow LED State