Sun Microsystems X4240 Server User Manual


 
18 Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide August 2008
FIGURE 3-2 DIMMs and LEDs on Mezzanine Board
Isolating and Correcting DIMM ECC
Errors
If your log files report an ECC error or a problem with a DIMM, complete the steps
below until you can isolate the fault.
In this example, the log file reports an error with the DIMM in CPU0, slot 7. The
fault LEDs on CPU0, slots 6 and 7 are on.
To isolate and correct DIMM ECC errors:
1. If you have not already done so, shut down your server to standby power mode
and remove the cover.
2. Inspect the installed DIMMs to ensure that they comply with the “DIMM
Population Rules” on page 11.