Sun Microsystems X6450 Server User Manual


 
Appendix B Using the BIOS Configuration Utility to Configure the Sun Blade RAID 5 Expansion Module 47
Note Hot-plugging of hard disk drives is NOT supported during periods when
the controller is busy performing actions on logical drives, such as building,
rebuilding, or migrating RAID volumes.
Hot-Unplug Removal Conditions
Hot-unplug removal of HDDs is supported under the following conditions:
The hard disk drive to be removed must not be a part of a logical device (its
status must be ‘available’).
After the hard disk drive is removed from the enclosure, you must perform a bus
scan by using the Rescan Drives option from the main menu of the Array
Configuration Utility (ACU).
You must confirm that the Disk Utility reports the correct configuration of the
attached target devices.
Hot-Plug Addition Conditions
Hot-plug addition of HDDs is supported under the following conditions:
After the hard disk drive is added to the enclosure, you must perform a bus scan
by using the Rescan Drives option from the main menu of the ACU.
You must confirm that the Disk Utility reports the correct configuration of the
attached target devices.
Hot-Unplug and Plug Replacement or Reinsertion
Conditions
Hot unplug and plug replacement reinsertion of HDDs is supported under the
following conditions:
The hard disk drive to be removed must not be a part of a logical device (its
status must be available).
If a hard disk drive is to be removed and replaced either into the same slot or into
a different unused slot using the same disk drive or a new disk drive, you must
perform a bus scan between the removal and the replacement steps, as follows:
a. Remove the selected hard disk drive.
b. Complete a bus scan by using the Rescan Drives option in the ACU.