TAG SV-2000-X2 Server User Manual


 
Operations Manual
SV-2000-X2 Server (CENTRIX / JHSV)
Part Number: 1008080 Page 55 of 82
Version 1.4. 01/12/2010
Figure 6-21 Hot-Swap of 2U Server Power Supply Module
5. Slide the replacement module into the power
supply.
6. Press firmly and evenly on the power module
until you feel the module seat in the back of the
power supply
6.11 Replacing a Hot-Swap Hard Drive
The system's hard drive Hot-Swap feature
enables you to remove a hard drive without
shutting down the operating system or turning
off the system power. The way in which you
remove a hard drive depends on the
application you are using and whether you are
replacing a drive, adding a new one, or
removing a drive permanently.
When you remove a drive using the Hot-Swap
operation, you need to stop the hard drive and
take it offline to remove the logical software
links to the hard drive, and to reconfigure the
file system so that it will now ignore the
removed drive. You might also have to
reconfigure your application software to
operate without the removed drive. Therefore it
is strongly recommended that you contact TAG
Technical Support at tech.support@tag.com
before attempting to Hot-Swap a hard drive.
For more information on contact information
see document back page.