Hardware Health Event Monitoring ScreenHardware Health Event Monitoring Screen
Hardware Health Event Monitoring ScreenHardware Health Event Monitoring Screen
Hardware Health Event Monitoring Screen
In this section, it allows you to monitor the status of the hardware on your system,
including the parameters of the CPU temperature, motherboard temperature, CPU fan
speed, chassis fan speed, and the critical voltage.
BIOS SETUP UTILITY
Hardware Health Event Monitoring
Select Screen
Select Item
F1 General Help
F9 Load Defaults
F10 Save and Exit
ESC Exit
v02.54(C)Copyright 1985-2005, American Megatrends, Inc.
CPU Temperature
M/B Temperature
CPU Fan Speed
Chassis Fan Speed
Vcore
+ 3.30V
+ 5.00V
+ 12.00V
:37C/98F
: 3400 RPM
:N/A
: 1.629V
: 3.306V
: 5.067V
: 11.890V
:31C/87F
Main Advanced
Boot Security Exit
H/WMonitor
Target Fan Speed
Fast
Middle
Slow
CPU Quiet Fan [Enabled]
Target CPU Temperature ( C) [50]
Tolerance ( C) [02]
Target Fan Speed [Fast]
CPU Quiet Fan
This item allows you to identify the temperature of CPU fan. If you set this
option as [Disabled], the CPU fan will operate in full speed. If you set this
option as [Enabled], you will find the items “Target CPU Temperature
( C)”, “Tolerance ( C)”, and “Minimun Fan Speed” appear to allow you
adjusting them. The default value is [Disabled]. You are allowed to enable
this function only when you install 4-pin CPU fan.
Target CPU Temperature (
C)
The target temperature will be between 45 C and 65 C. The default
value is [50].
Tolerance (
C)
The default value of tolerance is [2], which means the error of the
target CPU temperature will be within 2 C.
Target Fan Speed
Use this option to set the target fan speed. You can freely adjust the
target fan speed according to the target CPU temperature that you
choose. The default value is [Fast]. Configuration options: [Fast], [Middle]