Thermal Performance:
10
20
30
40
50
60
30 40 50 60 70 80 90 100 110 120
Ambient Temperature (
o
C)
Output Current (A)
NC (0.3 m/s, 60 LFM) 1.0 m/s (200 LFM) 2.0 m/s (400 LFM)
IMS LIMIT < 1.0 m/s (200 LFM) IMS LIMIT => 1.0 m/s (200 LFM)
iHA48060A012V-001 maximum output current vs.
ambient temperature at nominal input voltage for airflow
rates natural convection 0.3 m/s (60lfm) to 3.0m/s
(600lfm) with airflow from output to input.
iHA48060A012V-001 maximum output current vs.
ambient temperature at nominal input voltage for airflow
rates natural convection 0.3 m/s (60lfm) to 3.0m/s
(600lfm). Airflow from Vout (+) to Vout (-) with the
module output side on the left.
The thermal curves provided are based upon measurements made in TDK Innoveta’s experimental test setup that is
described in the Thermal Management section. Due to the large number of variables in system design, TDK Innoveta
recommends that the user verify the module’s thermal performance in the end application. The critical component
should be thermo-coupled and monitored, and should not exceed the temperature limit specified in the derating curve
above. It is critical that the thermocouple be mounted in a manner that gives direct thermal contact otherwise significant
measurement errors may result.