Technicolor - Thomson TG585 v7 Network Router User Manual


 
mbus Commands
486
E-DOC-CTC-20071119-0014 v1.0
mbus client exec
Execute mbus command
SYNTAX:
mbus client exec cmd = <{getpath|getcount|getnames|getvalues|
setvalue|addobject|deleteobject|subscribe|
unsubscribe|getaccessrights|setaccessrights}>
[param = <quoted string]>
[value = <quoted string]>
[gettype = <{parameter|path|object}]>
[depth = <number]>
[processcmd = <{enabled|disabled}]>
[onerrorrollback = <{enabled|disabled}]>
[usecallback = <{enabled|disabled}]>
[filter = <quoted string]>
[path = <quoted string]>
[flags = <[+/-]flag[+/-flag...]{indexpath
objidpath keystrpath uncommitted xref_localidx
xref_objid xref_keypath exact_depth
applyonparamsapplyrecursive typetreepath
non_persistent}]>
[accesslist = <quoted string]>
[action = <[+/-]flag[+/-flag...]{read write
attrchg}]>
[modifier = <{add|delete|allow_only|
allow_except}]>
[replytype = <{getallowed|getdisallowed|
getasconfigured}]>
[attribute = <{ar_archg|ar_read|ar_write|
param_cached|param_eventable|object_dynamic}]>
where:
cmd Mbus command name REQUIRED
param Parameter name OPTIONAL
value Parameter value to set OPTIONAL
gettype Get type elements (default=param) OPTIONAL
depth Number of levels to recurse, default=-1 (all) OPTIONAL
processcmd Process SET_VALUE command flag
(default=enabled)
OPTIONAL
onerrorrollback on error rollback flag (default=enabled) OPTIONAL
usecallback Use result callback function (default=enabled) OPTIONAL
filter The filter should be formatted as '(operator
operand operand)'. Possible operators are ==, !
OPTIONAL