Toshiba 245 All in One Printer User Manual


 
Before Calling Service Technician 199
Original/Copy paper-related items
Image trouble
Phenomenon Usual cause Countermeasure
An original jams. An original not acceptable for
the equipment is being used.
Check if the original is acceptable for the
equipment.
P.57 “Precautions for Reversing Auto-
matic Document Feeder (optional) / Auto-
matic Document Feeder (optional)”
Copy paper jams. Copy paper not acceptable
for the equipment is being
used.
Check if the copy paper is acceptable for
the equipment.
P.40 “Paper types not acceptable”
The size of the copy paper in
the drawer or on the bypass
tray is not registered prop-
erly in the equipment.
Register the size of the placed copy paper
properly.
P.49 “Preparation 3 - Registering Size
of Paper Placed”
P.64 “Bypass copying”
Jammed paper is located in
a place you cannot see eas-
ily.
See the message on the display to
recheck the position where the paper jam
has occurred.
P.176 “Paper Jams”
There is no gap between the
side guides and paper in the
drawer. Or the gap is too
wide.
Adjust the gap between the side guides
and the paper properly.
P.41 “Placing paper in drawers”
There is a gap between the
paper and the end guide in
the drawer.
Do not allow any gap between the paper
and the end guide in the drawer.
P.41 “Placing paper in drawers”
Multiple feeding occurs. Paper is clinging to each
other.
Fan the paper well and place it again.
Phenomenon Usual cause Countermeasure
The density of the copy
image is light.
Toner has run out. “Toner empty” appears on the display
when toner has run out. Replace the toner
cartridge if the message appears.
P.190 “Replacing Toner Cartridge”
The copy density is set
lighter.
Make the density darker if you use the
manual copy density mode. Or use the
automatic copy density mode.
The transfer charger wire is
dirty.
Clean the transfer charger wire.
P.206 “Cleaning transfer charger”
The density of the copy
image is dark.
The copy density is set
darker.
Make the density lighter if you use the
manual copy density mode. Or use the
automatic copy density mode.