Tests and Diagnostics
3-174 [CONFIDENTIAL] Qosmio F60 Series Maintenance Manual (960-796)
3.37 Maintenance (WinPE&FreeDos) Test Program Supplementary
Information
3.37.1 Outline
Describes notices and restrictions on using this program
3.37.2 Notices and Restrictions (Win PE T&D)
1) CPU Stress
W
hen the CPU stress checkbox is checked, it is recommended that this test be conducted in
the Simple mode.
If CPU stress is applied in the TIMER Test and the USB Test in the test items, an error
occurs.
2) External ODD Boot
If you run this maintenance tool from the CD, boot the system from the built-in ODD.
For the models in which ODD is not built, boot the system from the USB memory.
3) VIDEO Test
If the VIDIO test and other test are executed simultaneously (Multitasking), the test status
cannot be shown on the WinPE T&D main screen due to the VIDIO test.
4) LAN Test
To conduct the LAN test, be sure to connect the LAN router with DHCP to the PC. Do not
connect the LAN router to the external Network for safety reason. In addition, if the router
without DHCP or Hub is connected to the PC, the test fails with an error.
5) ODD、USB Test
Do not remove the CD containing this T&D test program or the USB memory during the test.
This CD or this USB memory include an operational program for the test, if it is removed,
the test cannot be continued and ends in an error.