LQ500
2
range, which is the upper limit setting range.
Resolution:
Meter size 50 mm (2”)
80 mm (3”)to
300 mm (12”)
Resolution 0.002%TS 0.001%TS
Note 1: Above values are the results of commuting
ability in the phase measurements of the
converter.
Note 2: Density (consistency) determination
resolution for sample reagent;
Meter size
50 mm
(2”)
80 mm (3”)to
300 mm (12”)
Density(consistency)
determination repeatability
0.1%TS 0.05%TS
* The density (consistency) determination resolution
stated above is defined due to manufacturing
limitation to make reagents with stable distribution
and a minimum difference of fluid density
(consistency).
<Notice>
1. Install a sample tap near the LQ500 as close
as possible to get an accurate density
(consistency) measurement using the LQ500.
2. Take several samples in rapid sequence for
more accurate density (consistency)
measurement with less human error factors.
Environmental conditions:
Items Temperature range Humidity range
Standard: 0 to 50 deg.C
(32 to 122 deg.F)
Detector
Option: -20 to 50 deg.C
(4 to 122 deg.F) (*1)
Converter
0 to 50 deg.C
( 32 to 122 deg.F)
5 to 85%RH
(no condensation)
*1 A rubber heater is installed at the RF part of the
detector.
Need to prepare an additional power supply either
100Vac type or 200Vac type for it by yourself.
Determine one of them at the specification code.
This option is available for detector only.
Structure: Converter;IP65,
Detector:IP67, Watertight
Note: Outdoor installation is possible. However,
provide a sunshade for the converter section if
direct sunlight is unavoidable.
Microwave power: 10 mW
Vibration resistance:
No resonance to the following levels of
vibration:
(1) No failure for 5 to 150 Hz with the following
acceleration in each device for 30 minutes in
each axis of X, Y, and Z (90 minutes);
Converter: 4.9 m/s
2
, Detector: 25m/s
2
(2) No failure for 5 to 150Hz with the following
acceleration in each device for 3 minutes in
each axis of X, Y, and Z, 10 times (90
minutes as total);
Converter: 4.9 m/s
2
, Detector: 25m/s
2
Note: Avoid using the LQ500 in an environment with
constant vibration.
Cables: See the Table 2
Table 2. Cable specifications
Cables Between detector
(RF part)and converter
(*1)
Specifications
Power supply
(24Vdc)
Communi-
cation
Power
supply
cable of
LQ500 (*2)
Cable type
CVVS-2C-2S
CVVS-5C-
1.25S
CVV-3C-2S
Cross-sectional
area (*3)
2 mm
2
1.25 mm
2
2 mm
2
Number of cores 2 5 3
Cable diameter (*4)
11 to 13
mm
2
11 to 13
mm
2
11 to 13
mm
2
*1 10m (32.8 ft) length is packed as standard.
*2 Need to prepare this cable by the customer.
*3 Need to use a sheathed cable.
*4 If the diameter of the cable is smaller than the inside
diameter of the packing, enlarge the cable diameter to
the same size as the packing by wrapping around the
cable.
This dimension is coming from a diameter of the
cable gland of the LQ500.
Conformance to European Community Directives:
• EMC directive 89/336/EEC
• The low voltage 93/68/EEC
• PED 97/23/EC (Note l)
Note: See table 6 in detail.
Approved hazardous locations certification:
UL/CUL Class I, Division 2, Groups A, B, C and
D (UL/CULonly for explosion proof)
Weight: Refer to Outline Dimensions (Table 3).
Part 15 of the FCC rules: Certified.
■
Detector Specifications
Meter size: 50mm (2”), 80mm (3”), 100mm (4”),
150mm (6”), 200mm (8”), 250mm
(10”), and 300mm (12”)
Flange standard and maximum working pressure:
Flange standard Maximum working pressure
ANSI Class 150 1 MPa (150 psi)
DIN10 and BS10 1 MPa (10 bar)
DIN 16 1.6 MPa (16 bar)
JIS 10K 1 MPa (10 kgf/cm
2
)
Note: Each product was passed a hydraulic test under
twice pressure rate for 15 minutes toward the
specification.
Fluid temperature:
0 to 100 deg.C (32 to 212 deg.F) without freezing
and bubbles conditions
Allowable fluid conductivity:
Meter size Fluid conductivity
50 mm (2”) 20 mS/cm maximum
80 mm (3”) 16 mS/cm maximum
100 mm (4”) 15 mS/cm maximum
150 mm (6”) 10 mS/cm maximum