Toshiba LQ500 Power Supply User Manual


 
LQ500
9
Table 4. Type Specification Code
(LQ500 Density (consistency) Meter)
TYPE CAT Code SPECIFICATION
1 2 3 4 5 6 7 8 9
10 11 12 13 14
L Q 5 0 0 Microwave Density (Consistency) Meter
A Standard
Meter Size
0 5 50mm (2")
0 8 80mm (3")
1 0 100mm (4")
1 5 150mm (6")
2 0 200mm (8")
2 5 250mm (10")
3 0 300mm (12")
Mounting Style
B JIS 10K flange connection
C ANSI 150 flange connection
F DIN 16 flange connection
Purpose
A Standard
B for PED (150 to 300 mm
(6" to 12") for EU) (Note 1)
C for UL/CUL Hazardous locations
type
Wetting parts
A SCS14A cast (Equivalent to 316L
SS) pipe (standard)
B SCS14A cast (Equivalent to 316L
SS) pipe with teflon PFA coating for
sticky application
C SCS14A cast (Equivalent to 316L
SS) pipe for abrasive application
(Note 2)
D Hastelloy C pipe
Cable length between detector
(RF part) & converter
A 10 m (32.8 ft) (standard)
B 20 m (65.6 ft)
C 30 m (98.4 ft)
D 40 m (131.2 ft)
E 50 m (164 ft)
X None (Note 3)
Optional specifications
None (standard) (blank codes are
required.)
A B Pipe buffing type
A C -20 to 50 deg.C (-4 to 122 deg.F)
environment temperature
specification, 200 to 240 Vac power
supply type of LQ500
A D Pipe buffing type with -20 to 50
deg.C (-4 to 122 deg.F) environment
temperature specification, 200 to 240
Vac power supply type of LQ500
A E -20 to 50 deg.C (-4 to 122 deg.F)
environment temperature
specification, 100 to 120 Vac power
supply type of LQ500
A F Pipe buffing type with -20 to
50deg.C (-4 to 122deg.F)
environment temperature
specification, 100 to 120 Vac power
supply type of LQ500
Note 1: The specification of PED (Pressure Equipment
Directive) is required from 150 to 300 mm (6" to
12") when the installation location is in the Europe.
Note 2: The differences between standard type are RTD
sensor and Applicator window.
Note 3: Toshiba recommends to using our specified cable.
Table 5. Type Specification Code
(AF900 Hand-held Terminal)
Model Specification Code
12345 6 7 8 9 10 11 12
Description
AF 90 0 Hand-held terminal
L Q 3 For use with LQ series
A Display language English
A A 3 Standard
Table 6. PED matrix
Meter Size
mm 50 80 100 150 200 250 300
Flange
inch 2 3 4 6 8 10 12
DIN16 SEP Certified
DIN10 SEP Certified
ANSI150 SEP Certified
SEP: Not required the PED.
Certified: The PED is certified.
Check your flange type and its meter size of the LQ500
whether it corresponds to the PED or not when its
installing location is in the Europe.
If yes, you need to choose the code “B” at the 10th
column in the specification code (Table 4)
Specifications are subject to change without notice.
Printed in Japan 2006-11 (TDOC)
© TOSHIBA Corporation 2003
All Rights Reserved.
Misuse of this product can result in damages to property or human injury.
R
e
a
d
r
e
lat
ed
man
u
al
s
c
ar
e
f
u
ll
y
be
f
o
r
e
us
in
g
thi
s
p
r
oduc
t
.
ISO9001 and ISO14001 are certified.