Toshiba M10 Personal Computer User Manual


 
4.35 Fluorescent Lamp 4 Replacement Procedures
Installing the fluorescent lamp
To install the 14.1-inch WXGA LG fluorescent lamp, follow the steps below and refer to
figures 4-72 to 4-75.
Assembly of Cover Ass’y Bottom (L), Sheets, Light guide, Tape Adhesive and Board Ass’y
1. Detach a release paper from Double Tape at the Cover Ass’y Bottom (L)1.
2. Assembly of Cover Ass’y and Screw (2Points)2.
CAUTION: Maximum value of torque with Screw should be below 2.5kgf.
3. Assembly of Light Guide and Sheets3.
CAUTION: No penetration of foreign body is indispensable with any scratch on the
surface of each Sheets and Light guide.
4. Assembly of Tape adhesive4 used for Sheets fixing (4Point).
2. Assembly of Board Ass’y5.
CAUTION: Pressure or stress should not be given on PCB and COF.
Figure 4-72 Replacing 14.1-inch LG fluorescent lamp (WXGA) (5)
TECRA M10 Maintenance Manual (960-685) [CONFIDENTIAL] 4-115