Toshiba RKP004Z Network Card User Manual


 
5. Operation in Top View Mode
5-2
2 After selecting the position of a figure you want
to change, specify/confirm another figure with
the control dial.
(In this example, a frequency of 30.0Hz is specified.)
Functions of function keys
The functions keys allow you to select the position
or decimal place of each figure (operation
frequency) you want to increment or decrement with
the control dial.
: Selects the position of hundreds.
: Selects the position of tens.
: Selects the position of ones.
: Selects the first decimal place.
When you confirm the frequency specified, the screen goes back to the top window
of Top View Mode.
To change the frequency during operation
Press the control dial during operation to display the operation panel operation
frequency menu and turn the control dial to change the setting.
5.2 Using an EASY key function
The [F1] function key can be used as a substitute for the EASY key on the inverter’s
main operation panel. When the name of the function assigned to the [F1] key is
displayed in the lower left corner of the window, the [F1] key can be used as the EASY
key.
“Quick” : Function of switching between Quick
mode and Standard Setting mode
(parameter F750=0)
“Panel” : Function of switching between Operation
Panel and Remote
(parameter F750=2)
(When used with a VF-AS1 inverter)
“Loc/Rem” : Function of switching between Local and
Remote
(parameter F750=2)
(When used with a VF-PS1 inverter)
“Update” : Function of updating the Peak/Minimum
Hold setting
(parameter F750=3)
* The shortcut key function (parameter F750=1)
cannot be used. Even if the parameter is so set, the
name of the function is not displayed on the screen.
Basic Parameters
FC
×1000 ×10 ×1
Output frequency 0.0Hz
30.0Hz
min=0.0 max=60.0
Panel fre
q
uenc
y
×100
F1
F2
F3
F4
F1
F2 F3
F4
Quick
Panel
(When used with a VF-AS1
inverter)
Loc/Rem
(When used with a VF-PS1
inverter)
To
p
View Mode
FWD 60.0 Hz STOP
0.0 Hz
Ln
g
Quick
---