Toshiba RKP004Z Network Card User Manual


 
7. Operation in Status Monitor mode
7-1
In this mode, you can monitor various kinds of statuses and information, such as the
operating status of the inverter, information on the terminal board, and trip information.
Functions of function keys
: Brings you to the Top View Mode.
: Displays the previous window.
: Displays the next window.
: Brings you to the Parameter Setup Mode.
Here are the items that can be monitored in this mode and an explanation of them.
These items are the same as those that can be monitored with the inverter’s main
operation panel.
Items displayed Description
Display
of details
Rotative direction
Rotating direction -
Frequency reference
*1
Set value and current value of parameter F711 v
Output current
*1
Set value and current value of parameter F712 v
Input voltage
*1
Set value and current value of parameter F713 v
Output voltage
*1
Set value and current value of parameter F714 v
Torqu e
*1, *2
Set value and current value of parameter F715 v
PBr overload
*1, *2
Set value and current value of parameter F716 v
Inverter overload
*1, *2
Set value and current value of parameter F717 v
Motor overload
*1, *2
Set value and current value of parameter F718 v
Input terminal 1 :
S4,S3…R,F
Input terminal board information (Standard
terminal board)
v
Input terminal 2 :
L8,L7…L1
Input terminal board information (Optional
terminal board)
v
Output terminal 1 :
FL…OUT2
Output terminal board information (Standard
terminal board)
v
Output terminal 2 :
R4…OT3
Output terminal board information (Optional
terminal board)
v
Version of APP-CPU
CPU version information (Application) -
Version of MOT-CPU
CPU version information (Motor) -
Past trip # 1 (latest)
Trip history information 1 (latest) v
Past trip # 2
Trip history information 2 v
Past trip # 3
Trip history information 3 v
Past trip # 4
Trip history information 4 v
Parts replacement alarm
Parts replacement alarm information v
Cumulative run time
Cumulative run time -
*1: The display item shows the case of a default setting.
*2: These items are not displayed when the LCD panel is used with a VF-PS1 inverter.
Status Monitor Mode
Real-time information
To
p
Prm
Rotative direction FWD
Frequency reference 60.0Hz
Output current 22%
Input voltage 99%
Output voltage 50%
7. Operation in Status Monitor Mode
F1
F2
F3
F4
F1 F2 F3 F4