Toshiba U840W Laptop User Manual


 
You can change the Real Time Clock settings in the BIOS setup utility.
Please refer to Troubleshooting for further information.
The RTC battery does not charge while the computer is turned off even if
the AC adaptor is attached.
Care and use of the battery pack
This section provides the important safety precautions in order to handle
your battery pack properly.
Refer to the enclosed Instruction Manual for Safety and Comfort for
detailed precautions and handling instructions.
The computer's RTC battery should be replaced only by your dealer or
by a TOSHIBA service representative. The battery can explode if not
properly replaced, used, handled or disposed. Dispose of the battery
as required by local ordinances or regulations.
Charge the battery pack only in an ambient temperature between 5
and 35 degrees Celsius. Otherwise, the electrolyte solution might leak,
battery pack performance might deteriorate and the battery life might
be shortened.
Charging the batteries
When the power in the battery pack becomes low, the DC IN/Battery
indicator will flash amber to indicate that only a few minutes of battery
power remain. If you continue to use the computer while the DC IN/Battery
indicator flashes, the computer will enable Hibernation Mode so that you do
not lose any data, and automatically turn itself off.
You must recharge a battery pack when it becomes discharged.
Procedures
To recharge a battery pack, connect the AC adaptor to the DC IN 19V jack
and plug the other end into a working outlet - the DC IN/Battery indicator
will glow amber while the battery is being charged.
Use only the computer connected to an AC power source or optional
TOSHIBA Battery charger to charge the battery pack. Never attempt to
charge the battery pack with any other charger.
Charging Time
The following table shows the approximate time required to fully charge a
discharged battery.
Satellite U840W series
User's Manual 4-13