CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when setting the jumper. Failure to observe this caution could result in damage to, and
subsequent failure of, the Device.
Set the Coax Grounding Jumpers
Note: Modify the settings for J11 and J12 only if necessary.
Jumpers 11 and 12 (located on the circuit board near the coax ports) provide a
grounding feature so that the SCSCF30xx-10x Device complies with the G.703
specification where:
The output coax port is connected to chassis ground.
A provision to connect the input coax port to chassis ground is provided.
The factory settings for these two jumpers are:
Jumper 12 (jumpered) = Output coax port is connected to chassis ground.
Jumper 11 (not-jumpered) = Input coax port is not connected to chassis ground.
The jumpers are located on the circuit board inside the Device housing. To set the
jumpers:
1. Using a small screwdriver, remove the four (4) screws that secure the cover
and carefully remove the cover from the Device.
2. Locate the jumper on the circuit board.
3. Using small needle-nosed pliers or similar device, move the jumper to the
desired position. (Refer to the above drawing.)
4. Carefully replace the cover on the Device and replace the four (4) screws that
secure the cover to the Device.
J
11 J12
No Jumper
Jumper
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Installation -- Continued
Install the Coax Cable
1. Locate or build coax cables with female connectors installed at both ends.
2. Connect the coax cables to the Device as described:
Connect the female TX cable connector to the male TX port.
Connect the female RX cable connector to the male RX port.
3. Connect the coax cables to the other device (switch, workstation, etc.) as
described:
Connect the female TX cable connector to the male RX port.
Connect the female RX cable connector to the male TX port.
Install the Fiber Cable
1. Locate or build fiber cables with male, two-stranded TX to RX connectors
installed at both ends.
2. Connect the fiber cables to the local SCSCF30xx-10x Device as described:
Connect the male TX cable connector to the female TX port.
Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the remote SCSCF30xx-10x Device as described:
Connect the male TX cable connector to the female RX port.
Connect the male RX cable connector to the female TX port.
Connect fiber cable
to media converter
as shown.
Connect fiber cable
to other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
RX
TX
RX
TX
Connect the
coax cable to the
Media Converter
as shown
Connect the
coax cable to the
other device as
shown