Transition Networks SCSCF30XX-10X Network Cables User Manual


 
10
SCSCF30xx-10x
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
6. Is Data Transfer Failing?
YES
Verify the local copper connection by starting a local copper loop-back
(set the loop-back switch on the local Device to “CL”) and then use a bit error
test unit at the local location to run a bit error test.
Verify the local fiber connection by starting a local fiber loop-back at the
remote location (set the loop-back switch on the remote Device to “FL”) and
then use a bit error test unit at the local location to run a bit error test.
Verify the remote copper connection by starting a local copper loop-back
at the remote location (set the loop-back switch on the remote Device to
“CL”) and then use a bit error test unit at the remote location to run a bit
error test.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
Proceed to step 7.
Copper Fiber Copper
Local
Converter
Remote
Converter
Bit Error
Test Unit
Remote
Device
Copper Fiber Copper
Bit Error
Test Unit
Local
Device
Remote
Converter
Local
Converter
Copper Fiber Copper
Bit Error
Test Unit
Local
Device
Remote
Converter
Local
Converter
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
11
Declaration of Conformity
Name of Mfg: Transition Networks
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.
Model: SCSCF30xx-10x Series Device
Part Number: SCSCF3011-100, SCSCF3013-100, SCSCF3014-100,
SCSCF3015-100, SCSCF3016-100, SCSCF3017-100,
SCSCF3018-100, SCSCF3019-100, SCSCF3029-100,
SCSCF3029-101, SCSCF3029-102, SCSCF3029-103,
SCSCF3039-100
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the SCSCF30xx-10x to which this declaration refers is in
conformity with the following standards.
EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 Subpart B; CFR 21 subpart J
61000-3-2:1995+A14:2000; 61000-3-3:1995;
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
February, 2009
Stephen Anderson, Vice-President of Engineering Date
7. Is the SDC (Signal Detect / Coax) LED illuminated yellow?
YES
A failure of the remote unit connected to the coax interface has caused
an Alarm Indication Signal (AIS) on the coax interface. Correct the
remote unit failure.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
Proceed to step 8.
8. Is the SDF (Signal Detect / Fiber) LED illuminated yellow?
YES
A broken coax link has caused an Alarm Indication Signal (AIS) on the
fiber interface. Correct the coax link failure.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
AIS on coax link
Original Fault
Coax Fiber Coax
AIS on fiber link
Original
Fault