Tripp Lite OMNIVS1500 Power Supply User Manual


 
5
MUTE/TEST Button:
Silence the UPS On-Battery Alarm: Pressandholdthisbuttonto
silencetheUPSon-batteryalarm,aseriesofshortbeepsfollowedby
abriefpausethatisactivatedwhentheUPSisprovidingACpower
frombattery.Note:Whenthebatteryisnearlydepleted,thelow
battery alarm—a continuous beep that cannot be silenced—will warn
toshutdownconnectedequipmentimmediately.
Run a Self-Test: Torunaself-test,leaveconnectedequipmenton.
WiththeUPSpluggedinandON,pressandholdthebuttonuntilthe
UPSbeeps(about2seconds)thenreleaseit.
Self-Test Results:AllLEDswillbelit(excepttheAVRLED)andthe
UPSwillemitseveralshortbeepsasitmomentarilyswitchesto
battery to test charge and load capacity. The test will last up to 10
seconds.Iftheinverterisoverloaded,the“ ”LEDwillstaylitand
theUPSwillcontinuetobeepafterthetest;ifthishappens,remove
someoftheloadfromthe“UPS/Surge”outletsandruntheself-test
again.Ifthebatteriesareweak,the“ ”LEDwillstaylitandthe
UPSwillcontinuetobeepafterthetest.Ifthishappens,lettheUPS
chargeitsbatteriesfor12hoursandrepeatthetest.Ifthecondition
persists,contactTrippLiteforservice.CAUTION:Donotunplugthe
UPStotestitsbatteries.Thiswillremovesafeelectricalgrounding
and may introduce a damaging surge into network connections.
Indicator Lights
AllIndicatorLightdescriptionsapplywhentheUPSispluggedintoan
AC outlet and turned on.
LINE POWER:ThisgreenlightwillilluminatewhenevertheUPSis
ON and receiving normal AC line power.
BATTERY POWER:ThisyellowlightwillilluminatewhentheUPSis
providingequipmentwithbatterypower.
REPLACE BATTERY: This red light will illuminate continuously after
theUPSrunsaself-testtoindicatethatthebatteryisweak.Ifit
remainslitafterallowingtheUPStochargefortwelvehoursand
runningasecondself-test,contactTrippLiteforservice.
OVERLOAD: This red light will illuminate continuously to indicate that
theUPSisoverloadedwhentheUPSisprovidingpowerfrombattery
oraftertheUPSrunsaself-test.Ifitlightsup,immediatelyremove
someoftheequipmentconnectedtothe“UPS/Surge”outletsand
runaself-test.LargeoverloadsmaycausetheUPStoshutdown.
Automatic Voltage Regulation (AVR): This green light will
illuminatewhenyourUPSisautomaticallycorrectinghighorlowAC
voltage.TheUPSwillalsoclickgently.Thesearenormal,automatic
operationsofyourUPS,andnoactionisrequired.
Basic Operation
201109015-93-3103.indb 5 9/9/2011 9:50:06 AM