6. Reboot the system and enter the FastBuild Utility main menu.
7. Select 5 to rebuild the array.
FastBuild ™ Utility 1.xx © 199x-200x Promise Technology, Inc.
[Rebuild Array Menu]
Array No RAID Mode Total Drv Capacity (MB) Status
Array 1 Mirror 2 16126 Critical
Array 2 —— —— —— ——
Array 3 —— —— —— ——
Array 4 —— —— —— ——
[Keys Available]
[] Up [] Down [ESC] Exit [Enter] Select
8. Highlight the array with “Critical” status and press Enter.
FastBuild ™ Utility 1.xx © 199x-200x Promise Technology, Inc.
[Rebuild Array Menu]
Array No RAID Mode Total Drv Status
Array 2 Mirror 2 Critical
Stripe Block: Not Available
[Select Drive for Rebuild]
Channel:ID Drive Model Capacity (MB)
1: Slave QUANTUMCR8.4A 8063
[Keys Available]
[] Up [] Down [ESC] Exit [Enter] Select
9. Highlight the replacement drive under [Select Drive for Rebuild].
10. Press Enter. All existing data on the replacement drive will be written over with mirrored
information from the array drive. A progress bar will appear on the screen.
11. Reboot the system when the process is completed.