5
Step 3.
Install the 9800 FlexFit plug.
Cable guide
Ground contact
Indicator post
Back wall
Cover
T
E
ST
Indicator
light
Ground-fault
unit
Reset button
Test button
K
eep
d
ry
Ga
rder a
u s
ec
3A. Prepare the cable.
Cleanly cut off the end of the cable. Push back the braid 3/4" (2
cm) and then twist the end of the braid around the cable to
ensure the braid strands are not sticking up.
Note: The clear plastic wrap does not need to be removed.
3C. Complete the connection.
Screw down the cable guide, alternating between the two
screws, until the cable guide is flush with the indicator posts
and the screws bottom out.
3B. Insert the cable.
Insert the heating cable all the way into the cable guide until the
cable hits the back wall.
Be sure no braid wire strands enter cable
guide.
3D. Install the cover.
Install the cover by tightening the screws completely.
Note: The screws will require many turns before the cover
starts to close.
Back wall
Indicator
post
3/4"
(2 cm)
3/4
0
in
cm
01
2
ENGLISH