Specifications
Sensitivity 12dB SINAD
25.005 MHz (AM) ........................................ 0.5 µV
40.840 MHz (FM) ........................................ 0.3 µV
49.900 MHz (FM) ........................................ 0.3 µV
118.800 MHz (AM)........................................ 0.5 µV
127.175 MHz (AM)........................................ 0.5 µV
135.500 MHz (AM) ....................................... 0.5 µV
138.150 MHz (FM)........................................ 0.3 µV
162.400 MHz (FM) ....................................... 0.3 µV
173.225 MHz (FM) ....................................... 0.3 µV
406.875 MHz (FM)........................................ 0.3 µV
453.250 MHz (FM) ....................................... 0.3 µV
511.9125 MHz (FM) ..................................... 0.3 µV
806.000 MHz (FM)........................................ 0.4 µV
857.200 MHz (FM)........................................ 0.4 µV
954.9125 MHz (FM) ..................................... 0.4 µV
Operating Temperature:
Normal ........................................... –20°C to +60°C
Close Call ...................................... –10°C to +50°C
Scan Rate: ............... 50 channels per second (max)
Search Rate
Normal ..........................60 steps per second (max)
Hyper .......................... 180 steps per second (max)
Priority Sampling ..................................... 2 seconds
Scan Delay: ............................................ 2 seconds
IF Rejection (at 162.4 MHz) ......................... 100 dB