Vidikron Vision 15ET Projector User Manual


 
Operation
48 Vidikron Vision Model 15 Installation/Operation Manual
Phase: Adjust the phase if the image (usually from an RGB source) shows shimmer or
“noise.” Pixel phase adjusts the phase of the pixel sampling clock relative to the incoming
signal. The effect of this control is similar to that of a tracking control on a VCR.
For best results, use a good test pattern such as a smooth gray consisting of a clear pattern
of black and white pixels, or a similar “half on, half off” graphic image. (You may find that
you can stabilize the image at more than one point. Use either setting in this case.)
Reset: Select Reset from the YUV/RGB Adjust menu to restore the position, clock and
phase settings to their factory-default values.
OSD Timeout: This timer controls how long the menus remain on-screen after selecting
them. Select a time-out period of 0, 5, 15 or 60 seconds. When you set the
OSD Timeout to 0,
the menus remain on-screen until you hide them by pressing MENU.
Vertical Correction (Vision 15ET/CineWide only): To achieve the proper image geometry
with the secondary anamorphic lens, select
Vertical Correction from the Installation menu.
Then, use the or button to change the native aspect ratio of the display, in small
increments.
The range is from 0 through 5 in increments of 1. Each increment reduces the image height
by one percent. A value of 5, for example, reduces the image height by 5 percent.
Information Select Information from the Main Menu to see projector status information: the
currently-active source, input signal resolution, aspect ratio, picture memory and lamp
usage. This menu also displays the projector serial number.
Should you ever need to contact Vidikron Technical Support, this information will help them
answer your questions or resolve product performance issues.
Information
Source HDMI
Resolution 720x480
H. Frequency 15.7 KHZ
V. Frequency 59.8 HZ
Aspect Ratio 16:9
Picture Memory ISF Night
Lamp Hours 450
Firmware 0014.006
Serial VIP015VM0803001