Wasp Bar Code WLS 8400 FZ Scanner User Manual


 
Maintenance and Technical Specifications
3-7
Technical Specifications
Table 3-2. Technical Specifications
Item
Description
WLS 8400FZ WLS 8400ER
Power Requirements 4.5 - 14VDC
Stand-By Current 50mA (max)
Power Source Depending on host:
host powered
external power supply
Decode Capability UPC/EAN, Bookland EAN, UPC/EAN with supplementals, Code 128, UCC/
EAN 128, ISBT 128, Code 39, Trioptic Code 39, Code 93, Code 11, Interleaved
2 of 5, Discrete 2 of 5, Codabar (NW-7), MSI, RSS.
Beeper Operation User-selectable: Enable, Disable
Beeper Volume User-selectable: Three levels
Beeper Tone User-selectable: Three tones
Scan Repetition Rate 36 scans/second
Yaw Tolerance ± 50° from nominal ± 60° from nominal
Pitch Tolerance ± 65° from nominal ± 65° from nominal
Roll Tolerance ± 20° from nominal ± 10° from nominal
Print Contrast Minimum 25% minimum reflectance differential, measured at 650 nm.
Ambient Light Immunity
Indoor:
Outdoor:
450 Ft Candles (4,842 Lux)
8,000 Ft Candles (86,080 Lux)
450 Ft Candles (4,842 Lux)
4,000 Ft Candles (43,040 Lux)
Durability 6.5 ft (2.0 m) drops to concrete
Operating Temperature -22° to 122° F (-30° to 50° C)
Storage Temperature -40° to 158° F (-40° to 70° C)
Humidity 5% to 95% (non-condensing)
Weight (without cable) 12.35 oz. (350 g) 12.56 oz. (356 g)