Wells-Gardner D9410 Series Computer Monitor User Manual


 
Wells-Gardner Electronics Corporation
FEATURES:
I²C BUS control.
The monitor is designed with I²C BUS control for simplifying the circuitry.
Automatic mode recognition of preset factory modes
No control pots to wear out
SET UP:
Setting up your monitor is easy. All you have to do is make a few simple connections
and adjustments. The procedure is as follows:
START UP:
Your monitor starts up automatically when you insert the power plug to power source.
Signal Cable Connection.
Connect the 15pin-signal cable to the source and lock both screws to ensure that the
monitor is properly grounded.
D type 15pin connector:
PIN NO. DESCRIPTION PIN NO. DESCRIPTION
1 VIDEO RED 9 N.C.
2 VIDEO GREEN 10 GROUND
3 VIDEO BLUE 11 N.C.
4 N.C. 12 SDA
5 N.C. 13 HOR-SYNC
6 VIDEO RED GROUND 14 VER-SYNC
7 VIDEO GREEN GROUND 15 SCL
8 VIDEO BLUE GROUND