1. Introduction
Network equipment sometimes "locks-up", making it impossible to communicate. The
RPB+ Remote Power Boot Switch can switch AC power on 5 individually controlled plugs,
allowing attached equipment to reset (re-boot).
ASCII commands are sent to the RS-232 Control Port to select plugs, and specify On, Off,
or Boot operations. A convenient Status Screen shows On/Off conditions at each plug.
RPB+ features include a security password, Location I.D. field, and plug labels to identify
the device connected to each plug.
Features:
Remotely Toggles AC Power to Five Separate Outlets.
Serial RS232 Control Port Interfaces Directly with a PC or External Modem,
Allowing Local or Remote Control.
Status Display Shows Plug Labels and On/Off Conditions.
Simple ASCII Commands for On, Off, or Boot (Off/On).
User-Selectable Re-Boot Cycle Duration (Off Time).
User-Programmable Password Feature.
User-Programmable Location I.D.
User-Selectable Echo Mode.
User-Programmable Plug Labels.
User-Programmable Power-Up Defaults.
Requires Only One Rack Space.
Available in 115 VAC or 230 VAC Configurations