Xantech 680-10 Switch User Manual


 
2
680-10
CAUTION: While the RC68+ can be used as a handheld remote control, it is highly recommended it not
be given to the final user for the following reasons:
Since it includes adjustable code groups, the user may inadvertently alter the installer configurations.
Also, since the user will require IR commands from other brands of equipment to control the total system,
in addition to those of the 680-10, all commands should be consolidated into one learning device, for ease
of use.
APPLICABLE RC68+ BUTTON DESCRIPTIONS
(With the "D" Overlay. Refer to Fig. 2)
Outlet Numbers (1 through 6).
These numbers identify the row of button commands that apply to each AC Outlet on the 680-10.
Code Group Numbers.
The 680-10 is capable of being set to 30 different IR code groups. The code groups are identified by
the numbers and letters that are on the face of each button.
NOTE: When shipped from the factory, the 680-10 is set to code group number 88.
Be sure to
set the RC68+ to the same number!
It may be necessary to change the 680-10 to a different code group if it is used in a common IR bus
controlled system with other Xantech 680-10's, to avoid mutual interaction.
Refer to the RC68+
instructions for code group setting details and procedures!
Outlet Command Modes.
Depending on the installation, you may want to have the 680-10 respond to IR commands in different ways.
The basic modes of operation for each outlet on the 680-10 are as follows:
OFF -Turns the power OFF to the selected outlet.
ON - Turns the power ON to the selected outlet.
These dedicated OFF and ON commands are
helpful when sending power commands "blind"
from secondary rooms when you have no visual
aid for status.
TGL - (Toggle Mode) - Switches power ON to the
selected outlet when the TGL command is sent
and OFF when it is sent again. If the outlet is ON,
it will turn OFF-- if it is OFF it will turn ON when
the code is sent.
MMT- (Momentary Mode) - Turns the selected outlet
ON when the code is sent. The ON condition
remains only as long as the MMT code is being
sent. The outlet is normally OFF.
GP-ON (Group ON). - This button (labeled F8 on the
button face) causes the 680-10 to turn all 6 AC
outlets ON at the same time. GP-ON overrides
all individual settings.
NOTE: OFF, ON and TGL (toggle) operation for
any individual outlet will still operate after Group
ON is executed.
GP-OFF (Group OFF). - This button (labeled D8 on
the button face) causes the 680-10 to turn all 6
outlets OFF (or any selected single outlet).
OFF ON TGL MMT
OFF ON TGL MMT
OFF ON TGL MMT
OFF ON TGL MMT
OFF ON TGL MMT
OFF ON TGL MMT
GP-ON
GP-OFF
D
1
3
4
5
6
2
80 48 10 90 01
00 C0 50 D0 41
40 A0 30 B0 21
20 E0 70 F0 61
60 88 18 98 09
08 A8 38 B8 29
28 E8 78 F8 69
68 C8 58 D8 49
E1 89 C9 A9 E9
71 19 59 39 79
F1 99 D9 B9 F9
Place the
"D" Overlay
on the RC68+
Code Group
Numbers
(on face of each
button)
Group-ON
Group-OFF
RC68+
Outlet
Command
Modes
(for 6 outlets)
Outlet Numbers
(1 through 6)
Fig. 2 RC68 Programmer