Xerox Nuvera
®
100/120/144 EA Digital Production System - Customer Expectations Document
- 13 -
Environmental Factors
Environmental Factor Minimum Maximum
Temperature 50
o
F (10
o
C)
(Tested to 60° F (15.6
o
C))
87
o
F (30.6
o
C)
(Tested to 80° F (26.7
o
C))
Humidity 15% RH
(Tested to 15%)
85% RH
(Tested to 80%)
Heat Emission (approximate)
(SFM / Scanner, Printer Module, MFF Professional)
2,322 BTU / HR
(Standby)
18,715 BTU / HR
(Running)
Heat Emission (approximate)
(SFM, Printer Module, BFM)
2,452 BTU / HR
(Standby)
19,023 BTU / HR
(Running)
Power Consumption (approximate)
(SFM / Scanner, Printer Module, MFF Professional)
0.680 kw
(Standby)
5,480 kw
(Running)
Power Consumption (approximate)
(SFM, Printer Module, BFM)
0.718 kw
(Standby)
5,570 kw
(Running)
SFM / PM / MFF Professional 6.2 B - Standby 8.6 B - Running
SFM / PM / BFM 6.6 B - Standby 9.0 B - Maximum
SFM / PM / FTM 7.2 B - Standby 9.0 B - Running
Noise
(Measured per ISO
7779 and declared
in Bel per ISO
9296)
SFM / PM / FTM / DS5000 7.2 B - Standby 9.1 B - Running
Altitude (above sea level) 0 10,000 ft.