Yamaha DRCX Computer Hardware User Manual


 
24
CHAPTER2 Ethernet Unit
LIN-CHEK (Login check)
Use this parameter to set whether or not to check the connection while the client is
connected to the controller.
If making a login check is selected here, then always make the user name and the
password check when connected to the controller. In this case, the client cannot con-
nect to the controller if data stored within the controller does not match data sent from
the client. However, if the login check is not selected here, then no check of the con-
nection is made and communication is possible right away.
Input range : 0 or 1
Meaning : 0: No login check
1: Login check
Default value : 1
LIN-USER (Login user name)
Use this parameter to set the user name when making the login check.
When the login check is used, the user name set here must entered so the client can
connect to the controller.
Characters that can be input are alphabet letters A to Z, a to z, numbers 0 to 9, and
symbols ! “ # $ % & ’ (*) + - . : = ? @ [\] _ ` {|} (All regular pitch letters.)
Input range : 1 to 8 characters
Default value : USER
LIN-PASS (Login password)
Use this parameter to set the password when making the login check.
When the login check is used, the password set here must entered so the client can
connect to the controller.
Characters that can be input are alphabet letters A to Z, a to z, numbers 0 to 9, and
symbols ! “ # $ % & ’ (*) + - . : = ? @ [\] _ ` {|} (All regular pitch letters.)
Input range : 1 to 8 characters
Default value : PASSWORD
LOUT (Logout processing)
Robot operation can stop automatically when the client terminates the connection
with the controller.
Input range : 0 or 1
Meaning : 0: Continue robot operation
1: Stop robot operation
Default value : 0
* If the TELNET connection is cutoff due to an error, then robot operation stops