Zebra Technologies 17080100000 All in One Printer User Manual


 
105
Configuration
Standard Control Panel Parameters
1/7/10 Xi4™/RXi4™ User Guide P1009874-002
Select ZPL Mode
The printer remains in the selected mode until it is changed by this
parameter or by using a ZPL/ZPL II command. The printer accepts label
formats written in either ZPL or ZPL II, eliminating the need to rewrite any
ZPL formats that already exist. See the Programming Guide for ZPL, ZBI,
Set-Get-Do, Mirror, and WML for more information on the differences
between ZPL and ZPL II.
Default Value: ZPL II
Range: ZPL II, ZPL
To change the value shown:
1. Press PLUS (+) or MINUS (-) to toggle between the options.
Select Media Power-Up Option
This parameter sets the action of the media when you turn on the printer.
Default Value (non-RFID printers): CALIBRATION
Default Value (RFID printers): FEED
Selections: CALIBRATION, LENGTH, SHORT CAL, NO MOTION,
FEED
Calibration adjusts sensor levels and thresholds, determines length,
and feeds the media to the next web.
Short Cal sets media and web thresholds without adjusting sensor
gain, determines length, and feeds the media to the next web.
Length determines label length using current sensor values, and feeds
the media to the next web.
No Motion tells the printer not to move the media. You must
manually ensure that the web is positioned correctly, or press feed to
position the next web.
Feed—feeds the labels to the first registration point.
To change the value shown:
1. Press PLUS (+) or MINUS (-) to scroll through the options.
Table 8 • Printer Parameters (Sheet 15 of 22)
Language/Parameter
Action/Explanation