EM220II
Rev. 1.00
- 15 -
Mobile Printer
iOS SDK API Reference Guide
2-16 Result Code
Code DEFINE
Value
Description
BXL_SUCCESS
0
Success
BXL_NOT_CONNECTED
-1
Printer is not connected
BXL_NOT_OPENED
101
SDK is not open
BXL_STATUS_ERROR
103
Error in status check
BXL_CONNECT_ERROR
105
Connection failure
BXL_NOT_SUPPORT
107
Not supported
BXL_BAD_ARGUMENT
108
Wrong function arguments
BXL_BUFFER_ERROR
109
Error in MSR buffer
BXL_NOT_CONNECTED
110
Printer is not connected
BXL_RGBA_ERROR
111
Error while converting image file to
RGBA data
BXL_MEMORY_ERROR
112
Memory allocation failure
BXL_TOO_LARGE_IMAGE
113
Size of image file is too big while downloading
image to NV area
BXL_NOT_SUPPORT_DEVICE
114
The printer device does not support
BXL_READ_ERROR
301
Failure in data reception
BXL_WRITE_ERROR
300
Failure in data transmission
BXL_BITMAPLOAD_ERROR
400
Fail to read image file
BXL_BC_DATA_ERROR
500
Error in bar code data
BXL_BC_NOT_SUPPORT
501
Unsupported bar code type
BXLMSR_NOTREADY
602
Not MSR READY state
BXLMSR_FAILEDMODE
601
Not automatic read mode
BXLMSR_DATAEMPTY
603
No data read from MSR
1001H
Unknown command
1002H
Command cannot be executed
1003H
Incorrect number of arguments
1004H
First byte of unknown command of
invalid command
1005H
Response time out
1010H
Response error due to card reset,
or first byte of response is not valid
1012H
Message limit is exceeded. Maximum is 254
bytes, and card data is 248 bytes
1013H
Error in reading bytes from asynchronous
routine
1015H
Card mode is terminated
Card mode command needs to be transmitted
101BH
Transmission of command with
incorrect arguments
101DH
Incorrect TCK check byte
10A0H
Error in card reset response (unknown
protocol or TA1 byte recognition error),
unsupported card, no card response value for
card reset
10A1H
Card protocol error (T=0/T=1)
10A2H
Time out due to no card response
10A3H
Parity error
10A4H
Card has aborted chaining (T=1)
10A5H