Zebra Technologies ZM400201101L0T Printer User Manual


 
81
Configuration
Control Panel Parameters
3/27/07 ZM400/ZM600 User Guide 79695L-001 Rev. A
Select Backfeed Sequence
This parameter sets when label backfeed occurs after a label is removed in
some print modes. It has no effect in Rewind mode. This setting is
superseded by
~JS when received as part of a label format (see the ZPL
Programming Guide for more information).
Default Value: DEFAULT (90%)
Selections: DEFAULT, AFTER, OFF, BEFORE, 10%, 20%, 30%, 40%,
50%, 60%, 70%, 80%
To change the value shown:
1. Press SELECT to select the parameter.
2. Press
PLUS (+) or MINUS (-) to scroll through the options.
3. Press
SELECT to accept any changes and deselect the parameter.
Adjust Label Top Position
This parameter adjusts the print position vertically on the label. Positive
numbers adjust the label top position farther down the label (away from the
printhead) by the specified number of dots. Negative numbers adjust the
position up the label (toward the printhead).
Default Value: +000
Range: –120 to +120 dots
To change the value shown:
1. Press SELECT to select the parameter.
2. Press
PLUS (+) to increase the value.
3. Press MINUS (-) to decrease the value.
4. Press
SELECT to accept any changes and deselect the parameter.
Adjust Left Position
This parameter adjusts the print position horizontally on the label. Positive
numbers adjust printing to the left by the specified number of dots.
Negative numbers shift printing to the right.
Default Value: 0000
Range: –9999 to +9999 dots
To change the value shown:
1. Press SELECT to select the parameter.
2. Press
MINUS (-) to move the cursor.
3. Press
PLUS (+) to change between +/- and to increase the value of the
digit. For a negative value, enter the value before changing to the
minus sign.
4. Press
SELECT to accept any changes and deselect the parameter.
Table 12 • Printer Parameters (Page 20 of 24)
Parameter
Action/Explanation