Zhone Technologies 800 Network Card User Manual


 
1-4 IMACS System Release 5.1.6 Server Cards
Model No.
Running Head
ADPCM Card User Screens and Settings ADPCM Card
Table 1-2. ADPCM Card Main Screen Actions
Table 1-3 summarizes the ADPCM card configuration parameters and available settings.
These are also described in the following paragraphs.
Table 1-3. ADPCM Card Setting Options and Defaults
STATE
The State setting determines whether the port is active or inactive. When assigning ADPCM
engine pairs for WAN traffic, set the State setting to stdby (standby) for ports that are not yet
used or not yet configured. Set it to actv (active) for ports that are ready for use.
Setting the State to rdnt (redundant) for any port on an unused card will cause that card to act
as the redundant back-up for all of the other ADPCM cards in that unit. Once a card is
designated as a redundant ADPCM card the only way it can be used for regular ADPCM
traffic is to change the state of the selected port back to either actv or stdby.
When assigning ADPCM engine pairs from user cards, changing the port from stdby to actv
and saving the selection information on the user card screen will cause the system to
automatically assign an ADPCM engine.
When the engine is assigned from a user card, no changes can be made from the ADPCM card
screen to any of the fields.
Action Function
Save Saves changes to settings.
Undo Returns all settings to the last saved state.
Refresh Redraws the current screen with the latest information.
pg_Left Pages through the 64 engines (highest to lowest), 8 at a time.
pg_riGht Pages through the 64 engines (lowest to highest), 8 at a time.
SWitch Switches an active ADPCM card to its redundant mate.
Main Returns to the ADPCM Card Main Screen. If changes are made to settings
and not saved, users will be prompted to save or lose changes.
Parameter User Options Default
STATE stdby actv rdnt stdby
USER n/a uX-1 through uX-8 n/a
WAN/SERV n/a w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1 w4-2 none
TS n/a 01-24 01-31 01
ADPCM W/S w1-1 w1-2 w2-1 w2-2 w3-1 w3-2 w4-1 w4-2 none
ADPCM TS 01-24 01-31 01
TYPE n/a v&s v trnsp v&s
RATE n/a 24K 32K 40K 24K
SIG MODE n/a e&m fxs plar fxo user e&m
CODING n/a u-law a-inv u-law
TC CGA n/a idle busy idle