Zhone Technologies Network Device Network Card User Manual


 
Zhone Technologies, Inc. IMACS Product Book, Version 4
March 2001 Page 23
Table 7—Operational Modes
Model Mode Cross Connect Drop and Insert Terminate
880060 Bus-connect No Yes Yes
880460 Enhanced bus-
connect
No Yes Yes
880160, 880260,
880360
Cross-connect Yes Yes Yes
LED Indicators
Green for normal operation. Amber for card fault or test mode (amber
on new cards).
Code Storage
Models 880060, 880160, 880460 256K EPROM
Model 880260 512K EPROM
Model 880360 Configurable with maximum 8MB DRAM and 4MB Flash memory
Maximum number of WAN links
Model 880060 Up to 2 WAN links
Model 880160, 880260, 880360 Up to 8 WAN links
Model 880460 Up to 4 WAN links. WANs in slot W1 supports voice only operate in
either Terminate or Drop and Insert mode. WANs in slot W3 operate
in Terminate mode only and only terminate certain data ports.
Support for CPU redundancy
Model 880060 No
Model 880160, 880260, 880360,
880460
Yes
Support for WAN link redundancy
Model 880060 No
Model 880460 1:1—A WAN card in slot W2 provides backup for an identically
configured WAN card in slot W1. A WAN card in slot W4 provides
backup for an identically configured WAN card in slot W3.
Model 880160, 880260, 880360 1:N—A single model 8014 WAN card in slot W4 provides backup for
identically configured 8010 WANs in slots W1 through W3.
Support for Server Cards
Model 880060, 880460 No
Model 880160 Only ADPCM Server card
Model 880260, 880360 Support for all server cards
Standards Conformance
Bellcore GR-63-CORE Network Equipment-Building System (NEBS) Requirements: Physical
Protections
CE EN 500 81-1 Electromagnetic compatibility generic emission standard Part 1
Residential, commercial and light industry
CE EN 500 82-1 Electromagnetic compatibility generic immunity standard Part 1
Residential, commercial and light industry
CE EN 60 950/A2 Safety of information technology equipment including electrical
business equipment
UL 1950 UL Standard for Safety of Information Technology Equipment
CSA C22.2, No. 950 Safety of information technology equipment including electrical
business equipment