The Web configurator a user friendly configuration interface via user's web browser, which can be access by
typing in the LAN IP address of the Prestige in users web browser. To access the Prestige's web configurator
via web browser, the configuration PC must be in the same IP segment of Prestige and Prestige must be
reachable to the configuration station. (By default the Prestige LAN IP is 192.168.1.1)
What is the default LAN IP address and Password? Moreover, how do I change it?
The default LAN IP address is "192.168.1.1" and you can change the LAN IP in web configuration menu under
"LAN"->LAN TCP/IP, the default password is 1234. You can change the password once you enter the web
configuration menu under "SYSTEM" and press the Password tab. At the password screen type in the old
password and the new password and retype to confirm than press "Apply" button to save the change.
How do I upload the ZyNOS firmware code via embeded web configurator?
The procedure for uploading ZyNOS via embeded web configurator is as follows.
a. Log on into the web configurator.
b. Press "MAINTENANCE" from the left menu.
c. Press "F/W Upload" tab.
d. Press "browse" button and point to the directory where the firmware you want to upload is kept and
press "Upload" button.
e. It will prompt you the firmware is upload successful and Prestige will reboot.
How do I upgrade/backup the ZyNOS firmware by using FTP client program via LAN?
The Prestige allows you to transfer the firmware from/to Prestige by using FTP program via LAN. The
procedure for uploading ZyNOS via FTP is as follows.
a. To upgrade firmware, use FTP client program to put firmware in file 'ras' in the Prestige. After data
transfer is finished, the Prestige will program the upgraded firmware into FLASH ROM and reboot
itself. Note: Do not power off the unit after upload the file via ftp until the system LED have become
steady light up. Fail to due so may result in update fail and require RMA.
b. To backup your firmware, use the FTP client program to get file 'ras' from the Prestige.