LF
[Name] Print and line feed
[Format] ASCII LF
Hex 0A
Decimal 10
[Description] Prints the data in the print buffer and feeds one line, based on the current line spacing.
[Note] This command sets the print position to the beginning of the line.
[Reference]
ESC 2
,
ESC 3
.
CR
[Name] Print and carriage return
[Format] ASCII CR
Hex 0D
Decimal 13
[Description] When automatic line feed is enabled, this command operates the same as
LF
; when
automatic line feed is disabled, this command is ignored.
[Notes]
This command is set at the start-up, via the PROGRAMMING MODE
(see point
3.6.2- PROGRAMMING MODE
).
Sets the print starting position to the beginning of the line.
[Reference]
LF
DLE EOT
n
[Name] Real-time status transmission
[Format] ASCII DLE EOT
n
Hex 10 04
n
Decimal 16 04
n
[Range] <01>H
n
<04>H
[Description] Transmits the selected printer status specified by
n
in real-time, according to the following
parameters:
n
= <01>H: Transmit printer status
n
= <02>H: Transmit offline status
n
= <03>H: Transmit error status
n
= <04>H: Continuous paper sensor status
n
= <05>H: Paper sensor status
[Notes]
The status is transmitted whenever the data sequence <10>H<04>H<n>
( <01>H
n
<05>H) is received.
The printer transmits the current status. Each status item is represented by one-byte of
data.
The printer transmits the status without confirming whether the host computer can
receive data (in serial interface).
The printer executes this command upon receiving it.
This command is executed even when the printer is offline, the receiver buffer is full, or
there is an error status with a serial interface model.
If a not recovery error occurred, the bit 2 in the Printer Status (
n
=1) will be
indeterminate.
n
= <01>H:
Printer status
Bit OFF/ON Function
0 OFF Not used. Fixed to OFF
1 ON Not used. Fixed to ON
2 OFF Not used. Fixed to OFF
OFF Online
3
ON Offline
4 ON Not used. Fixed to ON
5 OFF Does not wait for online error recovery
ON Waits for online error recovery
6 - Undefined
7 OFF Not used. Fixed to OFF