Command and Response Table for SIS Commands (continued)
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Audio mutes
Mute audio
X@
*1Z Amt
X@
*1
]
Mute output
X@
audio (audio off).
Unmute audio
X@
*0Z Amt
X@
*0
]
Unmute output
X@
audio (audio on).
View audio mute status
X@
Z
X#]
Global audio mute
1*Z
Amt1
]
Mute all audio outputs.
Global audio unmute
0*Z
Amt0
]
Unmute all audio outputs.
Save, recall, and directly write global and room presets
NOTES:
• If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.
• If the room is nonexistent, the matrix switcher responds with the error code E21.
• The following characters are invalid or not recommended in preset names: + - , ` @ = [ ] { } ‘ “ ; : | \ and ?.
Save current configuration as a
global preset
X(
,
Spr
X(]
Command character is a comma.
Example:
9,
Spr09
]
Save current ties as preset 9.
Recall a global preset
X(
. Rpr
X(]
Command character is a period.
Example:
5.
Rpr05
]
Recall preset 5, which becomes the
current configuration.
Write room outputs
EX1)
,
X@
1
,
X@
2
, ...
X@
n
MR
}
Mpr
X1)
,
X@
1
,
X@
2
, ...
X@
n
]
See notes.
NOTES:
• A room can contain a maximum of 16 outputs.
• An output can belong to only one room.
• The maximum number of rooms (
X1)
) is 10.
• If no room name is assigned, the default name (
X1!
) is “
Room
#
X1)
••••”.
Example:
E
8,3,04,5,6MR
}
Mpr8,03,04,05,06
]
Outputs 3, 4, 5, and 6 are assigned to
room 8.
Read room outputs
EX1)
MR
}
X1!
,
X@
1
,
X@
2
, ...
X@
n
]
Example:
E
3MR
}
Room
•
#03
••••,
01
,
02
,
08
,
09
]
Outputs 1, 2, 8, and 9 are assigned to
room 3, which is named “Room #03”.
Save current configuration as a
room preset
X1)
*
X(
,
Rmm
X1)
•Spr
X(
]
Command character is a comma.
Example:
3*9,
Rmm03•Spr09
]
Save current ties as preset 9 for room 3.
Recall room preset
X1)
*
X(
.
Rmm
X1)
•Rpr
X(]
Command character is a period.
NOTE: X@ = Output number 01 – (maximum number of outputs for your model)
X# = Mute status 0 = off (unmuted) 1 = on (muted)
X( = Global or room preset number 00 - 32, 10 maximum for a room preset (00 = current configuration for view only)
X1) = Room number (for room presets) 10 max. (Each can have up to 10 presets (X(s) assigned.)
X1! = Name 12 characters (upper- and lower-case alphanumeric characters and / and spaces) max.
CrossPoint and MAV Series Matrix Switchers • Programming Guide 98