352 iSeries and AS/400e System Builder
Options for 3494 Models L12, L22, L10
#2713
#2714
#2715
IBM TotalStorage Master Console Features
The #2713, #2714, and #2715 features provide connection to an IBM TotalStorage Master Console to enable enhanced
remote support to improve availability. The IBM TotalStorage Master Console can remotely monitor each attached device
to determine if it is working properly and report any error alerts for the early detection of problems. Use of the IBM
TotalStorage Master Console can expedite microcode updates, reduce service times, and enhance local service. One of
these features must be ordered on any new 3494 Tape Library Model L12, or L22. They are recommended on every
installed 3494 Tape Library.
To connect a unit to an IBM TotalStorage Master Console, one of the following three features must be selected on the unit
based on the number of units attached to that master console facility in the installation.
#2713 Master Console for Service
This feature provides the IBM TotalStorage Master Console, an Ethernet hub and a cable and connectors for connection
of one of the above units to an IBM supplied modem to enable remote enhanced service. This feature should be specified
on the first unit in an installation connected to a master console facility. The Ethernet hub provides 14 additional
connections for cables supplied with feature #2714 or #2715.
#2714 Console Expansion
This feature provides an attachment cable for connection of one of the above units, and an Ethernet hub for expanding
the number of units that can be attached to the #2713 Master Console For Service. Up to 14 additional connections are
provided by this feature for connection of #2715 or another #2714.
#2715 Console Attachment
This feature provides a cable to attach a unit to the Ethernet hub provided by the #2713 Master Console for Service or
the #2714 Console Expansion. A maximum of 40 of feature #2715 can be included in a single master console facility.
#3511 Install Fibre Channel Drive
The #3511 must be added to the 3494 Model L12 or D12 frame when it is to contain any 3590 Model E1A or H1A Tape
Drive with the #9510 or #3510 Fibre Channel Attachment and the quantity is equal to the number of installed Fibre
Channel drives. The #3511 provides a Fibre Channel patch panel and the Fibre Channel cables from Fibre Channel
attached tape drives to the patch panel. The #5805, #5812, #5825, or #5861 Fibre Channel cables can be ordered on the
tape drive to connect from the patch panel to Fibre Channel adapters on host server systems or the SAN.
Maximum: Two in L12; six in D12. One feature is required for each Fibre Channel attached drive installed in that frame.
Plant or Field installation
Prerequisite: The 3590 Model E1A or H1A must have feature #9510 or #3510.
#5046
#9046
PCI Library Manager - Field/Plant
This feature provides the field or plant installation of a library manager with PCI architecture including a faster 1.2 GHz
processor and a mirrored dual disk drive, for performance and availability improvements in the 3494. If this feature is
added to a 3494 that includes Model HA1 Frames, feature #5046 must be ordered for both the Model HA1 Frames and
the Model L10, L12, or L14.
Maximum: One
Corequisite: The #5046 or #9046 is required when adding the #9040 High Availability Attachment feature to any installed
Model L1x that does not already have the #9020 Model B20, B10, or B18 Attachment feature.
#5047
#9047
LAN PCI LIbrary Manager Field/Plant Install
This feature provides the field installation of a library manager that supports EASH attachment of tape drives attached to
open systems and up to 64 LAN attached open system TCP/IP hosts. The Library Manager has a PCI architecture and
includes a 1.2 GHz processor and a mirrored dual disk drive, to help improve performance and availability in the 3494. If
this feature is added to a 3494 that includes Model HA1 Frames, the other Library Manager must be feature #5046, #9046,
or #9047.
This Library Manager does not come with four RS232 host connections and four tape control unit serial connections. If it
is required, the Base Tape Control Unit Attachment feature (#5225) must be ordered with this feature. Feature #5225 is
also required if the other Library Manager in the 3494 Tape Library that includes Model HA1 Frames is not feature #5047
or #9047.
Maximum: One.
Required: Feature #5047 (or #9047) is required when adding feature #9040 (High Availability Attachment) to any installed
Model Lxx that has a library manager shipped prior to 15 May 2000, and the Model Lxx does not contain feature #5046
or #9046 (PCI Library Manager) or feature #9020 (Model B20, B18, or B10 VTS Attachment).
Corequisite: Feature #5225, if RS232 host connection or base tape control unit serial connection to the Library Manager
is required (such as when replacing an older Library Manager with that connection requirement).