A SERVICE OF

logo

Technical Data GPS1200 119
Cable connectivity:
Event input For GX1200 with PPS/Event option and GRX1200 Pro
Pulse length: 1 ms
Leading edge: Coinciding with the beginning of each epoch.
Positive/negative edge: Selectable via RX1200.
Matched with an appropriate impedance of: 50
Socket: LEMO ERN.0S.250.CTL
Peak: 3.3 V = High
Pulse type: TTL, positive or negative going pulse
Pulse length: 125 ns at minimum
Voltage: TTL level, ~ 5 V, min. 3.3 V
Pin definition: Centre = signal, Case = ground
Socket: LEMO HGP.00.250.CTL