A SERVICE OF

logo

General Asynchronous Port Settings
5-4 PortMaster Configuration Guide
To set the port speed, use the following command—entered on one line:
Command> set S0|all speed [1|2|3] Speed
You can set
speed
to any of the following standard modem speed settings:
Parity Checking
Parity checking is off by default.
Setting Databits
You can set the number of databits per byte for a single asynchronous port or all
asynchronous ports. The default (8) is the most common.
You can set the databits for all the asynchronous ports simultaneously by using the set
all databits command.
T
o set databits, use the following command:
Command> set S0|all databits 5|6|7|8
Setting Flow Control
The PortMaster can use either software or hardware flow control to communicate with
the attached device to start and stop the flow of data. Because hardware flow control is
more reliable, Lucent recommends that you set software flow control to off and
hardware flow control to on.
To set software flow control to off, use the following command:
Command> set S0|all xon/xoff off
To set hardware flow control to on, use the following command:
Command> set S0|all rts/cts on
300 1200 4800 19200 57600 115200
600 2400 9600 38400 76800