21
DM-2A Mark II 2008-02-22
In normal (forward) mode, your gauge will increase the fan speed in order to achieve higher
pressures and decrease the fan speed in order to achieve lower pressures. Reverse mode is used
for advanced neutralization testing and sets the gauge in Reverse Control mode. While in this
mode, the gauge will increase the fan speed in order to reduce the pressure and decrease the fan
speed in order to increase the pressure. Reverse Control mode is enabled by setting the Reverse
Mode option to Yes.
For more information on adjusting your gauge for specific measurement standards, see
Appendix A, Configuring and Using Your DM-2A Mark II Gauge for Specific Standards
discussed later in this user guide.
DM-2A Mark II Dual-Channel Pressure Gauge User Manual
2: Working with the Setup Screen