A SERVICE OF

logo

20
MZ-N707
2. NV adjusted values modifying procedure
1) Select manual mode of the test mode, and set item number
336 (see page 14).
2) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
08.
3) Press the X key to write the adjusted value.
4) Select manual mode of the test mode, and set item number
741 (see page 14).
5) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
02.
6) Press the X key to write the adjusted value.
7) Select manual mode of the test mode, and set item number
771 (see page 14).
8) Adjust with the
[VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
6E.
9) Press the X key to write the adjusted value.
10) Select manual mode of the test mode, and set item number
772 (see page 14).
11) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
7C.
12) Press the X key to write the adjusted value.
13) Select manual mode of the test mode, and set item number
773 (see page 14).
AbcdGn **
3 36
**
: Adjusted value
Set LCD display
BatFlg **
7 41
**
: Adjusted value
Set LCD display
NiRec0 **
7 71
**
: Adjusted value
Set LCD display
NiRec1 **
7 72
**
: Adjusted value
Set LCD display
NiRec2 **
7 73
**
: Adjusted value
Set LCD display
14) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
7D.
15) Press the X key to write the adjusted value.
16) Select manual mode of the test mode, and set item number
774 (see page 14).
17) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
7F.
18) Press the X key to write the adjusted value.
19) Select manual mode of the test mode, and set item number
775 (see page 14).
20) Adjust with the [VOL +] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
81.
21) Press the X key to write the adjusted value.
22) Select manual mode of the test mode, and set item number
776 (see page 14).
23) Adjust with the
[VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
5B.
24) Press the X key to write the adjusted value.
25) Select manual mode of the test mode, and set item number
777 (see page 14).
26) Adjust with the [VOL +] key (adjusted value up) or [VOL --]
key (adjusted value down) so that the adjusted value becomes
7B.
27) Press the X key to write the adjusted value.
NiRec3 **
7 74
**
: Adjusted value
Set LCD display
NiRec4 **
7 75
**
: Adjusted value
Set LCD display
NiPb 0 **
7 76
**
: Adjusted value
Set LCD display
NiPb 1 **
7 77
**
: Adjusted value
Set LCD display