10
SERVICE CONNECTIONS
DIRECT STEAM, VSX36D FIG. 3
LEGEND
A. COLD SUPPLY WATER CONNECTION:
1
⁄4” TUBING FOR COLD WATER
CONDENSER, AND BOILER FEED.
B. STEAM SUPPLY CONNECTION:
3
⁄4” NPT FOR STEAM COOKING. (A STEAM
PRESSURE REDUCING VALVE IS MOUNTED AS STANDARD AND SET FOR
10 PSI MAXIMUM INPUT TO UNIT.)
C. ELECTRICAL CONNECTION FOR CONTROLS: 120V/60HZ/1PH/300 WATT
MAXIMUM, POWER SUPPLY WITH GROUNDING WIRE REQUIRED. (FOR
OTHER THAN 120 VOLT SUPPLY CONSULT FACTORY FOR LOCATION OF
THIS CONNECTION.)
D. DRAIN: COPPER TUBE COMPARTMENT & EXHAUST GROUP APPROXIMATELY
2" DIAMETER. (PROVIDE AN OPEN AIR GAP TYPE DRAIN DIRECTLY UNDER
UNIT FRAME. DO NOT CONNECT SOLIDLY TO ANY DRAIN CONNECTION.)
NOTE: DIMENSIONS WHICH LOCATE THE ABOVE CONNECTIONS HAVE A
TOLERANCE OF ± 3 IN. (± 75 MM). NORMAL DIMENSIONS ARE IN INCHES.
DIMENSIONS IN ( ) ARE IN MILLIMETERS.
EQUIPMENT CLEARANCES
TO COMBUSTIBLE CONSTRUCTION
REAR: 2 IN. MIN. (50 MM.)