A SERVICE OF

logo

24
CONTROLS — COMPARTMENT (Fig. 14)
The upper section of the steamer consists of two
cooking compartments. Each compartment functions
independently with its own controls, and is a separated,
sealed steam chamber during the cooking operation.
Gasket Plate Screw (Not Shown) — a stainless steel
screw on the gasket plate immediately adjacent to each
corner of the gasket allows adjustment of the gasket if
necessary.
Door Gasket (Not Shown) — provided on each
compartment door and ensures proper sealing of the
cooking compartment. CAUTION: Damage to the
gasket sealing surface, such as nicks or cuts, will
cause steam leakage.
Door Striker (Not Shown) — provides positive
latching of door.
Ready Light (Green) — when lit, indicates appliance
is ready for the cooking cycle.
Cooking Light (Red) — when lit, indicates appliance
is in the cooking phase.
Timer — use to set desired cooking cycle time. Timer
range is 0-60 minutes.
Fig. 14
LIGHTING THE STANDING PILOT (GAS BASE
GENERATORS ONLY) (On Steamers So Equipped)
1. Before lighting the pilot, both the burner and the
pilot must have been off for at least 5 minutes.
2. Turn power switch (upper left of generator cabinet)
to OFF. Be sure gas to the steamer is turned ON.
3. Turn knob of combination control valve to PILOT.
With a lit taper, ignite pilot while depressing knob of
combination control valve. Keep knob depressed
for about 1 minute after pilot is lit.
4. Release knob. Pilot should continue burning. If
not, repeat Steps 1 through 3.
5. Turn knob counterclockwise to ON.
Shutdown
1. Turn gas service valve and power switch OFF.
2. Close water inlet valve.
OPERATING STEAMERS WITH INTERMITTENT
PILOTS (GAS BASE GENERATORS ONLY)
1. Before lighting the pilot, both the burner and the
pilot must have been off for at least 5 minutes. Do
not attempt to manually light the pilot.
2. Turn knob of gas combination control valve
counterclockwise until it stops at the ON position.
3. Turn boiler power switch to ON position (light on).
4. The electrode will begin sparking and pilot will light.
5. Ensure pilot light has lit by observing pilot flame.
6. The pilot light will remain lit as long as the boiler
power switch is in the ON position.
7. The cycling pressure switch will open and close the
gas combination control valve, which will in turn
cycle the main burner.
COOKING
TIMER
READY
TIMER
PL-50860
COOKING
READY
Ready
Light
Ready
Light
Timer
Timer
Cooking
Light
Cooking
Light