3Com 4500 Switch User Manual


 
Important Safety Information 95
WARNING: Your Power Supply Unit was shipped with a plastic cover
protecting the RPS (-48V DC) power inlet. If a DC supply is connected to
the unit, this cover should be removed and retained. Should the DC
supply be removed at any point, this cover must be replaced to ensure
safe operation of the unit.
WARNING: The appliance coupler (the connector to the unit and not the
wall plug) must have a configuration for mating with an EN60320/IEC320
appliance inlet.
WARNING: The socket outlet must be near to the unit and easily
accessible.
WARNING: This unit operates under SELV (Safety Extra Low Voltage)
conditions according to IEC 60950. The conditions are only maintained if
the equipment to which it is connected also operates under SELV
conditions.
WARNING: France and Peru only:
This unit cannot be powered from IT
supplies. If your supplies are of IT
type, this unit must be powered by 230V (2P+T) via an isolation
U.S.A. and
Canada
The cord set must be UL-approved and CSA certified.
The minimum specification for the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
10A.
The attachment plug must be an earth-grounding type
with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A,
250V) configuration.
United
Kingdom only
The supply plug must comply with BS1363 (3-pin 13 amp)
and be fitted with a 5A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and
be of type H03VVF3GO.75 (minimum).
Europe only: The supply plug must comply with CEE 7/7 (“SCHUKO”).
The mains cord must be <HAR> or <BASEC> marked and
be of type H03VVF3GO.75 (minimum).
Denmark The supply plug must comply with section 107-2-D1,
standard DK2-1a or DK2-5a.
Switzerland The supply plug must comply with SEV/ASE 1011.