3M 10700 Tablet Accessory User Manual


 
14
Installation and Setup (Continued)
1. Read and remove safety tag from pneumatic
"On/Off" valve.
2. Connect the main air supply line to the inlet
side of the On/Off valve using the barbed
fitting and hose clamp provided. The
customer supplied air hose
(8 mm [5/16 inches] Inner Diameter) must be
clamped tightly to the barbed fitting.
If another type of connector is desired, the
barbed fitting can be removed and replaced
with the desired 1/4-18 NPT threaded
connector.
Always turn the air valve Off when the air
supply line is being connected or
disconnected.
3. Turn the air supply on by turning the air On/Off
valve to On.
Note – The air valve has provisions for lock
out/tag out according to plant regulations.
4. Raise the upper drive assembly to full Up position
by turning the drive assembly raising switch
clockwise.
PNEUMATIC CONNECTION
Note: A precision regulator is used to balance
the top drive assembly. Due to the self-
relieving feature of this regulator, a small
amount of air continually vents to the atmo-
sphere. This is normal and amounts to
approximately 3 liter/min. [0.1 SCFM].
To reduce the risk associated with impact
hazards:
Always use appropriate supporting means
when working under the upper drive
assembly
WARNING
The case sealer requires a 5.2 bar gauge
pressure 110 liter/min [75 PSIG], @ 21°C, 1.01
bar [3.75 SCFM] compressed air supply. As
shown in Figure 3-1, an on/off valve, pressure
regulator, and filter are provided to service the air
supply.
Important: Use care when working with
compressed air.