Abit NI8 SLI Computer Hardware User Manual


 
3-6 Chapter 3
# Voltage Monitoring:
Click <Enter> key to enter its submenu:
µGuru Utility V0.09
OC Guru ABIT EQ
V
oltage Monitoring
Reading Shutdown
Enable
Beep
Enable
High
Limit
Low
Limit
(*)CPU Core Voltage 1.550V (*) (*) 1.89V 1.00V
(*)DDR Voltage 2.70V ( ) (*) 2.90V 2.10V
(*)DDR VTT Voltage 1.35V ( ) (*) 1.55V 1.05V
(*)CPU VTT 1.2V Voltage 1.22V ( ) (*) 1.45V 0.95V
(*)NB 1.4V Voltage 1.45V ( ) (*) 1.70V 1.10V
(*)SB 1.5V Voltage 1.55V ( ) (*) 1.80V 0.20V
(*)ATX +12V(24-Pin Connector) 11.77V ( ) (*) 3.00V 9.60V
(*)ATX +12V(4-Pin Connector) 11.71V ( ) (*) 14.40V 9.60V
(*)ATX +5V 5.03V ( ) (*) 6.00V 4.00V
(*)ATX +3.3V 3.39V ( ) (*) 3.95V 2.65V
(*)ATX 5VSB 5.06V ( ) (*) 6.00V 4.00V
↑↓:Move Enter:Select +/-/PU/PD:Value F10:Save ESC:Exit
All Voltages:
These items display the voltage of each element.
! Shutdown Enable:
Use <Space> key to enable system shutdown function. If the voltage of corresponding element is
higher/lower than the high/low limit, the system would automatically shutdown.
! Beep Enable:
Use <Space> key to enable warning beeps function. If the voltage of corresponding element is
higher/lower than the high/low limit, warning beeps will sound.
! High/Low Limit:
These items set the high and low voltage limit.
NOTE: The value of high limit must be set above the one of low limit.