Acer AcceleRAID 352 Network Card User Manual


 
BBM Functional Description
A-4 AcceleRAID 352 Installation Guide
Status Indication
Battery status can be checked, and the battery can be reconditioned, or
charged using the Intelligent Battery Backup Unit dialog box in Global
Array manager Client. This is accessed by selecting the Intelligent BBU
option on the Administration menu. Please refer to the Global Array
Manager Client Software Installation Guide and User Manual.
Battery and Charge Circuit
On-board Battery
The on-board battery is rated at 4.1 V with a capacity of 900 mAH. The
BBM has a DC-DC converter that converts 4.1 V to 3.3 V, which is the
nominal voltage required for the cache.
Battery Charger
Battery charging is automatically handled by the BBM. No manual
preconditioning needs to be performed by the user. If the battery capacity
falls below a predetermined level (which is likely to happen after a power
failure), the battery charger goes into a quick charge mode. The battery
charger will operate in a temperature range from 0°C to +45°C.
Disposition of Failed Batteries
Currently, requirements for disposal or recycling of rechargeable Lithium-
Ion batteries are under consideration by many agencies, both local and
international. Lithium-Ion batteries should not be punctured or incinerated
(the electrolyte can generate steam and cause the gas to explode).
The battery on the BBM contains the following text:
Li-Ion Battery. Must be disposed of properly.
Contact your local authorities to determine the appropriate method of
disposal.