Adaptec 5ANA-940 Network Card User Manual


 
B-2
ANA-5910/5930/5940 User’s Guide
User Error Messages
User error messages appear at the command tool or shell tool
windows.
Error Message Description
aatm,ume: Address
Registration Completed
The
atmo.sys
driver registered to the switch
successfully.
Note:
For the Bay Networks Switch, the
driver registration can take up to three tries.
The aatm,ume: Address Registration
Completed error message appears until the
address has registered with the switch. If
after three tries, the address cannot register,
check the ATM cables, and check the switch.
The problem may occur with only one port at
a time, and may occur at another port at a
different time.
aatm,ume:Link down,
no response from
switch
The link is down between the adapter and the
switch. Check the cable connection between
the adapter and switch; then check the
switch.
aatm,ume: Retrying... The
atmo.sys
driver is trying to register to the
switch again.
aatm,ume: Timeout
Waiting For Network
Prefix From Switch
The driver attempted to register to the switch,
but failed because the switch did not send the
network prefix during the time set by the
timeout value in the configuration file.
atmo.sys, unable to
bind.
Make sure that the VCI numbers are the same
in
acip.db
and
base.db
. If the numbers do not
match, the driver is not able to bind.
Error in Address
registration, will retry
Address registration
failed. exiting
The driver could not register with the switch
and failed.
Error Opening File
<ConfigFile>
Unable to open
configuration file
The driver could not open the specified
configuration file.