Adaptec 5ANA-940 Network Card User Manual


 
B-5
Windows NT Specific Error Messages and Diagnostics
Note:
The variable in a message refers to the return code.
Also, messages with the same solutions are listed together.
Driver Console Error Message Description
E1010 ATMO_SIG: UNABLE to GET
STATION ADDRESS
STOP DRIVER, RESTART aatmcnfg
The software was not able to obtain
address of the host from the ILMI
module of the driver. Enter
aatmcnfg -s
to stop the driver, and enter
aatmcnfg
to
restart.
E1011 ATMO_SIG: Q-SAAL
GENERAL CONFIG FAILURE
E1012 ATMO_SIG: Q-SAAL
DATA_LINK CONFIG FAILURE for
PORT variable
E1013 ATMO_SIG: SIG_VCC create
failed for lack of memory
E1014 ATMO_SIG: SIG_VCC create
failed status variable diag variable
E1015 ATMO_SIG: SIG_VCC bind
failed for lack of memory
E1016 ATMO_SIG: SIG_VCC bind
failed status variable diag variable
E1017 ATMO_SIG: Resource
UnAvailable
These errors occur when there is not
enough memory on the system.
Increase the amount of memory.
E1018 ATMO_SIG: QSAAL Transport
Layer DOWN
This error indicates that QSAAL
module of the driver lost connection
with the switch. Try stopping the
drivers and restarting them.