Local Configuration LTPS-UM-8013-03
24 August 30, 2002 D3LX CO and RMT Modules
4 Configure the fields as detailed in the Table 5 and assign the selections by pressing .
5 Repeat Steps 2 through 5 for each D3LX system installed in the chassis.
Press + for assistance when making selections.
Table 5. D3LX CO Configuration Fields–SCU V3.7 or later
Field Name Type Options Description Default
Unit Equip State Toggle EQUIPPED Establishes communication with SCU. Module
must be set to EQUIPPED before remaining
selections are allowed.
UNEQUIPPED
UNEQUIPPED No communication with SCU.
Unit Service State Toggle IN SERVICE Places the unit in service and allows equipment
alarm reporting by the SCU. Must be set to IS
for reporting of equipment alarms.
OOS
OUT OF SERVICE Removes unit from service and stops
equipment alarm reporting by the SCU.
Unit Protect State Toggle PROTECTED Line protection Unprotected
UNPROTECTED No protection
Optical Service State Toggle IN SERVICE Places facility in service and enables T2 alarm
reporting by the D3LX CO.
OOS
OUT OF SERVICE Removes facility from service and stops T2
alarm reporting by the D3LX CO.
Optical BER Alarm
Threshold
Toggle Set to OFF or set
between 10
-6
and 10
-10
The average Bit Error Ratios of both the
incoming optical signals are monitored by the
D3LX CO. By monitoring BERs, the D3LX CO is
capable of triggering a minor alarm when any of
the monitored signals degrades below the BER
threshold level.
10
-8
Optical BER Switch
Threshold
Toggle Range from 10
-4
to
10
-10
Sets the threshold at which the APS will be
executed.
10
-6
DS3 Provisioned
(set for each T1)
Toggle YES Brings up T1 default settings and allows
configuration changes.
NO
NO No configuration changes allowed.
DS3 Service State Toggle IN SERVICE Select IS after completing the remaining con-
figurations.
OOS
OUT OF SERVICE Leave this field at OUT OF SERVICE (versus IN
SERVICE) at this time to avoid undesirable
reporting of alarms.
DS3 Transmit LBO
Local
Toggle 0–225 ft., 226–450 ft. The DS1 signal output provides standard DSX
signal levels which can be compensated for at
various distances, such as cable length.
0–225 ft.
DS3 Transmit LBO
Remote
Toggle 0–225 ft., 226–450 ft. The DS1 signal output provides standard DSX
signal levels which can be compensated for at
various distances, such as cable length.
0–225 ft.
Continued
CTRL A
ENTER